Curve-based fan controller for Dell PowerEdge servers via iDRAC/IPMI. Python 3.13 · uv · ruff · ty.
Source: github.com/martinmiglio/breezed
breezed is a curve-based fan controller for Dell PowerEdge servers, driving iDRAC/IPMI with a multi-point temperature curve and linear interpolation between points so homelab racks stay quiet at idle and cool under load. Above the top curve point it hands control back to iDRAC's own automatic thermal management — the safety net is always one degree away. Logs are JSON on stdout; a Prometheus-format metrics socket is opt-in; adapters (IPMI transport) and speed policies (curve today, PID later) sit behind small Protocols, so either can be swapped without touching the core.
From PyPI:
pip install breezed
# or
uv tool install breezedTo deploy as a systemd service (the breezed binary needs privileges to talk to
iDRAC; daemon install stages the unit and re-execs under sudo once), run one
command and enter your password once:
breezed daemon installdaemon install stages the unit/env/config, then re-executes itself via sudo to
perform the fixed privileged steps (create the service user, install the runtime
under /opt, write the systemd unit, enable and start the service). Pass
--dry-run to print the steps without escalating. The user-level uv only
invokes breezed from the checkout; it is not copied into the system installation
and is not a service dependency.
breezed run --config /etc/breezed/breezed.toml --metrics-port 9762 -v # foreground daemon
breezed set 20 # one-shot 20% duty cycle
breezed auto # one-shot back to iDRAC automatic control
breezed status --config /etc/breezed/breezed.toml # snapshot: temps, RPMs, curve target
breezed validate breezed.toml --probe # check config; probe reads live tempThe daemon subcommands manage the systemd deployment:
breezed daemon install # one command, one sudo prompt
breezed daemon install --dry-run # print the privileged steps without escalating
breezed daemon status # report unit state and binary version
breezed daemon uninstall # one command, one sudo prompt; keeps env/configExit codes: 0 ok, 1 runtime error (e.g. IPMI failure), 2 usage/config error.
Machine-readable output is always JSON on stdout; errors go to stderr as text.
systemd is the only deployment path — no containers. daemon install stages
breezed.service, breezed.env, and breezed.toml into a private temp
directory, prints the privileged steps, then re-executes itself once via sudo
to perform them. uv installs and manages the runtime directly under /opt:
breezed daemon install
# one sudo password prompt; then:
sudoedit /etc/breezed.env
journalctl -u breezed -fdaemon install --dry-run prints the same steps without escalating, for review.
The sudo re-exec runs only a fixed, code-reviewed sequence — no free-form
commands, no shell — using the absolute path of the running binary, so it is
immune to sudo's secure_path.
The runtime step sets UV_TOOL_DIR=/opt/breezed,
UV_TOOL_BIN_DIR=/usr/local/bin, and
UV_PYTHON_INSTALL_DIR=/opt/breezed-python, then installs the current checkout
with --reinstall. The sequence creates the non-login breezed system user and
installs files with explicit ownership and permissions:
/etc/systemd/system/breezed.service:root:root, mode0644/etc/breezed/breezed.toml: invoking user and group, mode0664/etc/breezed.env:root:breezed, mode0640
The config and environment install steps run on first installation only and are skipped when those files already exist, so upgrades never overwrite tuned config or secrets.
Upgrading: update the checkout and run breezed daemon install again.
The uv tool install --reinstall step replaces the runtime in /opt; the config
and environment steps are skipped because those files already exist. breezed daemon uninstall mirrors install: one sudo prompt to disable and remove the
service and runtime, while /etc/breezed/ and /etc/breezed.env remain.
The metrics port is baked into the unit's ExecStart deliberately (netdata
scrapes it). To run without metrics, edit the unit to drop
--metrics-port 9762 and systemctl daemon-reload && systemctl restart breezed; note your edit will be overwritten by the next daemon install.
A fully commented example ships inside the package: see breezed.toml.example
in the breezed templates directory (also copied to /etc/breezed/breezed.toml
on first install, never overwritten after that).
Secrets never go in the config file: IDRAC_HOST, IDRAC_USER, and
IDRAC_PASSWORD come from the environment (/etc/breezed.env); host and user
may also live in the config, but environment variables win. The config
hot-reloads when its mtime changes; an invalid reload keeps the last good
config.
With the default unit, breezed serves Prometheus text format on
127.0.0.1:9762. Scrape URL for netdata's prometheus collector:
http://127.0.0.1:9762/metrics. Metric names: breezed_temp_c,
breezed_fan_percent, breezed_mode, breezed_ipmi_errors_total,
breezed_polls_total.
Manually controlling server fans means you are the thermal management system:
a bad curve can cook components or leave a server roaring at 100%. breezed
mitigates this by deferring to iDRAC automatic control above the curve top and
forcing AUTO again after repeated sensor-read failures — but you chose the
curve points, so choose them carefully. If anything looks wrong,